IMO Tier III certification of a methanol dual-fuel genset
At a Glance
In October 2026 we completed IMO Tier III certification tests under DNV supervision on a Volvo Penta genset converted to methanol dual fuel. Ecoexhaust supplied the DOC-DPF-SCR system and acted as certificate holder, answering for everything from the engine components to the final test report.
| Item | Details |
| Engine | Volvo Penta D16 marine diesel, rated 500 kW at 1840 rpm |
| Conversion | Methanol dual fuel by ScandiNAOS AB |
| Aftertreatment | Ecoexhaust DOC-DPF-SCR |
| Application | Variable-speed diesel-electric genset, permanent magnet generator built for a DC bus |
| Regulation | MARPOL Annex VI, NOx Technical Code 2008, IMO Tier III |
| Test cycle | E3, engine and SCR tested together (Scheme A) |
| Fuel modes | Pure diesel and methanol dual fuel |
| Certifying body | DNV |
| Client | Freire Shipyard |
| Ecoexhaust scope | Certificate holder, test campaign, measurements, NOx Technical File |
Challenge
A dual-fuel conversion takes an engine out of its approved engine family, so this genset needed a new EIAPP certificate covering both fuel modes. The existing Volvo Penta approval for the D16 family covers Tier I and Tier II only. Tier III requires the SCR to be certified together with the engine.
The genset was built for a ship’s DC bus, with converters behind the generator. With the generator bolted straight to the engine bell-housing, there was no shaft to fit a torque flange: the generator itself had to load the engine and measure its power.
During the project DNV also asked for the tests to cover methanol dual-fuel mode, not only diesel. Three things had to hold at once:
- the correct load at every mode point, held stable
- engine power measured through a traceable, calibrated chain
- documentation complete enough for DNV to approve without reopening it
Our role: certificate holder
As certificate holder we were responsible for the whole chain, not only the hardware we supplied:
- the original engine components and their IMO identification markings
- the dual-fuel modifications
- the DOC-DPF-SCR system and its urea dosing
- the test bench, the instruments and their calibration
- the measurements, the calculations and the NOx Technical File
In practice that meant one point of contact for DNV, and one team that had to answer every question. It also meant preparing the physical inspection of all IMO-marked components.

Choosing the right cycle and rating
We certified on the E3 cycle at 500 kW and 1450 rpm, because that is how this genset actually runs. Getting this wrong at the start would have invalidated every measurement that followed.
Cycle. A genset suggests the constant-speed D2 cycle. But this is a variable-speed diesel-electric set: the power management system lowers engine speed as load drops. Its operating line follows the E3 cycle, not D2.
Rating. The base engine is rated 551 kW at 1900 rpm. The conversion kit and the ship’s electrical design both set 500 kW at 1840 rpm as the continuous rating. That is the power the engine will deliver in service, so that is the power we certified.
The 75% point carries half of the result, so it had to be the most accurate one. On the bench the engine throttle sets speed and the load sets torque: two independent controls for every point.
Calibrated equipment, monitored sensors
Every number in the test report traces back to a calibrated instrument. The system’s own sensors were monitored throughout, but never used as evidence.
Calibration register. We mapped every measurement DNV requires to an instrument, a calibration certificate and the NTC 2008 Appendix 4 tolerance and validity period. Accredited (ISO/IEC 17025) calibrations covered the SCR inlet and outlet temperature sensors, the exhaust back-pressure sensor, the intake air thermohygrometer and the power analyzer. Humidity needs recalibration every month, so validity dates were tracked against the test schedule.
One reference for NOx. A chemiluminescence (CLD) gas analyzer was the only reference for NOx. The SCR control system’s electrochemical NOx sensors were logged for completeness.
Engine sensors. Factory ECU sensors carry production tolerances, not individual calibration certificates. Modifying them needs OEM approval. DNV accepted that, with the existing family approval, they did not need individual calibration. We offered verification against reference instruments instead.
ECU signals in dual-fuel mode. The engine ECU calculates load, torque and fuel rate from the diesel injection quantity only. In methanol mode it cannot see the methanol, so these signals under-read. We used none of them to set or verify a mode point.
Gravimetric consumption. Urea, diesel and methanol consumption were measured by weighing. The urea lines are too thin for a flow meter, and weighing methanol avoids extra joints and leak points. The scale was checked with certified reference weights.
Logged parameters. At DNV’s request we added continuous logging of exhaust temperature at the sampling point, charge air pressure and temperature, intake air temperature and humidity, back pressure before the SCR, ambient pressure and O2. Test fuel was commercial EN 590 diesel, agreed with DNV in advance and backed by a batch quality certificate.
Building the full NOx Technical File
We wrote the complete NOx Technical File ourselves, following NTC 2008 §2.4.1 and DNV’s guideline for EIAPP certification. The file covers both fuel modes and treats the engine and SCR as one certified unit.
- Engine identification and rating, with reference to the existing Volvo Penta family approval for diesel Tier II
- The dual-fuel conversion: operating modes, components and settings
- The SCR system as part of the engine: reactor, catalyst, dosing and control, per the IMO SCR guidelines (MEPC.291(71), as amended)
- NOx-critical components with their IMO identification markings
- Allowable setting and adjustment ranges
- Tier II / Tier III changeover logic for emission control areas
- Onboard verification procedure using the engine parameter check method
- Parent engine test report on the NTC 2008 Appendix 5 forms, with raw data and calculations
- Calibration records for every instrument used
- Fuel and reductant specifications
The calculations follow the Code to the letter. Exhaust mass flow comes from the carbon balance method, and the weighted result in g/kWh weights mass flows and powers separately, as the Code prescribes. Averaging per-mode g/kWh values instead is a common shortcut that can shift the result by several percent. At 1840 rpm the Tier III limit is about 2.0 g/kWh.
Comparing the two fuel modes:
- NOx: similar in pure diesel and in methanol dual fuel. Methanol does not remove the need for SCR.
- CO and HC: high at engine-out in methanol mode, especially at low load where unburnt methanol slips through. The oxidation catalyst reduces them effectively, provided it runs hot enough.
Methanol does not remove the need for exhaust aftertreatment. It changes what the aftertreatment has to deal with.
Partners
| Company | Role |
| Freire Shipyard | Client |
| Volvo Penta | Engine manufacturer |
| ScandiNAOS AB | Methanol dual-fuel conversion |
| Danfoss | Generator manufacturer, efficiency data |
| Instytut Transportu Samochodowego (ITS) | Pre-certification survey and metrology support |
| DNV | Certifying body |
Converting engines to alternative fuels or need IMO Tier III certification?
Contact us
Request a quote
Contact
-
Bruzdowa 106a/13
02-991 Warsaw
woj. mazowieckie
Poland -
+48 506 508 330
+48 600 501 050 -
info@ecoexhaust.eu